An electroformed nickel mesh sheet starts with a mesh pattern on a peripheral conductive substrate; nickel is deposited to the target thickness and the whole sheet is then lifted off. Mesh flatness describes the deviation of the free sheet from an ideal plane, while tension is the pull per unit length once the sheet is mounted on a frame. Nanning electroformed nickel mesh processing serves customers in Nanning and the surrounding area with a delivery and communication baseline that puts flatness, tension and thickness tolerance on one inspection sheet. On the floor the inspector lays the sheet on a granite surface plate, reads nine points with a dial indicator and judges flatness against ≤0.05 mm. After framing, a tension gauge takes a reading at each corner and at the centre; an out-of-spec sheet goes back for re-tensioning rather than being passed by feel.
Problems on the line tend to arrive in chains. If release stress is not relieved, the thin sheet curls into a shallow arc, lifting more than 0.1 mm at opposite corners on the plate, and corner tension readings finish several newtons away from the centre. Drive current density up to 4 A/dm² and the wall grains turn coarse with a hairy edge; stress concentrates at the hole rims during stretching and local slack appears before the gauge reaches 10 N. Shorten the cure of an AB glue frame and tension drops after 24 h, so the band written on drawings commonly received from customers in Nanning and nearby areas cannot be held. The rework bench keeps the three apart: curl goes back for a low-temperature anneal before framing, a hairy wall goes back for stripping and replating, and an under-cured bond means the frame is separated and glued again.
Parameter Window
• Electroformed nickel thickness 0.05–0.30 mm with ±3 μm tolerance, sampled at several points per sheet
• Mesh flatness ≤0.05 mm, taken as the largest deviation across nine indicator readings on a surface plate
• Hole roundness ±0.002 mm, profile captured on an optical comparator at 100x
• Wall roughness ≤0.01 μm; burr and wall finish respond to the same current density
• Tension 10–55 N with ±1 N internal control, re-measured once 24 h after framing
• Current density 1–4 A/dm², bath held at 23±2 ℃, with edge zones dropped one band
Manufacturing Process (8 Steps)
1. Drawing review — mark flatness, tension band and thickness tolerance on drawings commonly received from customers in Nanning and nearby areas.
2. Substrate preparation — control conductive-layer uniformity first, since local conductivity differences make the nickel thickness uneven.
3. Resist coating and exposure — size the mesh pattern to a profile the comparator can read, with hole roundness at ±0.002 mm.
4. Development — flush hole bases clean so resist residue does not turn into wall burr.
5. Electroforming — step current density through 1–4 A/dm² and hold the bath at 23±2 ℃.
6. Release and anneal — a low-temperature anneal relieves stress before the whole sheet is lifted off without curling.
7. Frame and stretch — let the AB glue frame stand until cured, then hold tension from 10–55 N to ±1 N.
8. Inspect and re-measure — nine-point flatness on the plate, four corners plus centre on the tension gauge, then read again after 24 h.
Core Advantages
1. Flatness is measurable — ≤0.05 mm enters the sheet as nine indicator readings, and a curled sheet is not forced onto a frame.
2. Tension is archived — 10–55 N is held to ±1 N, with both the framing reading and the 24 h reading kept.
3. Thickness is controlled — 0.05–0.30 mm sheet carries a ±3 μm tolerance, with sample points covering edges, centre and corners.
4. Walls stay clean — roughness ≤0.01 μm keeps stress from concentrating at hole rims during stretching.
5. Rework is sorted — curl goes to anneal, hairy walls back to replating and under-cured bonds to a re-glued frame.
6. Delivery is traceable — each sheet from nanning electroformed nickel mesh processing carries an inspection sheet stating a measured tension band.
Typical Applications
• Vibratory screening sheets, where flatness decides whether material spreads evenly across the mesh.
• Fine filtration sheets, where wall roughness ≤0.01 μm affects blinding and cleaning intervals.
• Paste printing meshes, where the 10–55 N tension is set against the drawing and squeegee stroke.
• Thin 0.05–0.30 mm sheets, supported throughout release and framing to prevent curl.
• Large-format sheets, relying on zoned temperature control to level thickness between edges and centre.
• Prototype lots for manufacturing customers in Nanning and nearby areas, re-measured sheet by sheet against the tension band on the drawing.
Design and Selection Notes
1. Put the tension band on the drawing first. Without a ±1 N internal-control basis, the upper and lower reading limits are argued over separately.
2. Measure flatness in the free state. A reading taken after framing mixes in stretching stress and says nothing about whether the sheet itself curls.
3. Current density is not the higher the better. Past 4 A/dm² the wall coarsens and stress drives toward the hole rims during stretching.
4. If tension drifts more than 1 N after 24 h, go back and re-check frame cure and glue-layer thickness.
5. Write the ±3 μm thickness tolerance together with the agreed sampling points; one point says nothing about the whole sheet.
6. Log wall roughness ≤0.01 μm and hole roundness ±0.002 mm separately instead of collapsing them into one remark about hole quality.
7. This process covers nickel mesh only; settle the material boundary at the drawing stage and do not extrapolate its parameters to non-nickel materials.
Putting the acceptance of nanning electroformed nickel mesh processing down to mesh flatness and tension is what lets a delivered sheet still match its drawing. While nickel grows to 0.05–0.30 mm in the bath, stress stays hidden under substrate constraint; lift the sheet and that constraint is gone, the thin metal curls, and the nine-point indicator reading of ≤0.05 mm becomes the first gate. Once framed, the tension gauge takes over: 10–55 N held to ±1 N, read again after 24 h, with large drops sent back for re-tensioning. Drawings from customers in Nanning and nearby areas turn into two records here, one surface-plate flatness sheet and one tension sheet covering four corners plus the centre. Tension is delivered on a measured basis, given as a band with its re-measure conditions rather than a promise of permanent tension without maintenance. Whether a whole lot can be accepted together depends less on one beautiful reading than on all readings landing on the same internal-control line; that is where nanning electroformed nickel mesh processing earns its value.
Contact:赖先生
Phone:+86 18938693450
Tel:0755-2708-8292
Email:yw9@zldsmt.com
Add:深圳市宝安区福永镇新和村福园一路华发工业园A3栋