Welcome: Shenzhen Zhuolida Electronics Co.TD
Language: Chinese ∷  English
Your location: Home > News > Company new

Company new

Step Stencil Double-Side Aperture Alignment Control: Exposure Datum and Etch Undercut

step stencil double-side aperture alignment control

A step stencil carries apertures on both faces: one layer of graphics faces the squeegee, the other sits against the PCB, and paste goes in one side and lands on the pad from the other. The two layers have to be concentric or the solder column will not stand straight. The alignment here is the registration between top and bottom aperture graphics, not the thickness ramp of the transition zone: that one governs step height and squeegee contact, this one governs whether the two apertures are offset. The imaging operator stacks both faces on the imager to measure the centres, and any sheet past ±7μm offset is pulled for rework on the spot. Step stencil double-side aperture alignment control takes the datum transfer error between the two faces plus the centre offset from unequal etch undercut, and pins both inside a remeasurable window.

Step stencils sent back from the line often show nothing wrong on the dimension report: the two apertures are simply not concentric. One lot pairing a QFN large pad with 01005s measured every single-side aperture inside ±3μm, yet stacking the faces showed a 10μm centre offset; the fine-pitch row laid its solder columns in crooked, three boards came up short, and wiping did not bring the volume back. The inspector re-stacked on a flash gauge with SPI also flagging the shortage, so the whole sheet went back for re-datuming. Another lot lost undercut control in the thick zone: slower chemistry exchange gave 6μm more undercut than the thin zone, one face shifted left and the other right, and on the press it clogged and cleared by turns. Then there was the double-side LDI that took its datum only from four corner targets: the half over the thick zone drifted 5μm with no remeasurement, the single-side checker passed everything, and only the paired view showed the two apertures half a web width apart; that one was scrapped outright. None of this is an out-of-tolerance bore. It is an exposure datum never remeasured and two-side undercut never balanced, and only step stencil double-side aperture alignment control reins it in.

Parameter Window

• Double-side alignment ±5μm paired with 8μm/8μm LDI resolution, both faces registered in one shot within 610×660mm

• Hold the two-side centre offset to ≤±7μm and re-overlay every sheet

• Pull the two-side undercut gap inside 3μm, single side 2–6μm classed to thick and thin zones, no universal value

• Stencil thickness 15–200μm in classes, film height difference logged per zone, the datum at the step checked on its own

• Minimum opening ≥25μm, Pitch ≥120μm, aperture spacing ≥50μm, bore accuracy ±3μm

• Tension 10–55N (±1N internal) and hardness 450–550HV, print life rechecked at 15000 cycles

Manufacturing Process (8 Steps)

1. Mark the thick and thin zones first, then set the two-face art, target layout and undercut compensation; the double-side settings of a flat substrate do not get copied.

2. Clean and conductivize the base, flatten it before lamination so the step neither blisters nor lifts.

3. Run double-side lamination and LDI at 8μm/8μm with ±5μm alignment, both target sets aligned in one shot and exposed layer by layer.

4. Hold concentration and time on each face separately; no residue at the step edge.

5. Grow the base at 1–4A/dm², then time the etch per thickness class to balance two-side undercut.

6. Peel the whole sheet from a low-stress corner, low-temperature anneal to relax the step root.

7. Imager and flash gauge measure both aperture centres while the checker scans outlines; anything past ±7μm offset is held.

8. Set tension to 10–55N, fit the AB adhesive frame, log datum and undercut data; if a target remeasurement drifts past 5μm, go back to the LDI station and re-align.

Core Advantages

1. Both faces inside ±7μm offset and the solder column stands straight — that is what step stencil double-side aperture alignment control buys you.

2. Target remeasurement and two-side undercut are logged per sheet, so an anomaly chases back to an exposure run.

3. With undercut balanced the area ratio stays honest and fine pitch clogs and bridges less.

4. Datum checked per zone means the transition no longer eats the alignment margin.

5. 450–550HV nickel alloy holds the aperture edge toward 15000 prints without dulling.

6. One datum set per lot, so the press needs no repeated alignment and test prints.

Typical Applications

1. Printing stencils mixing QFN large pads with 01005 fine pitch, where two-face concentricity bites hardest.

2. Composite plates with a step, where undercut in thick and thin zones has to be balanced apart.

3. 4–12 inch WLP ball-drop templates, where two-face alignment sets a consistent ball landing.

4. ABF substrate Ball and Flux plates, where paste crosses over unless the two-face graphics register.

5. Power modules printing large copper and fine signal leads on one board, where two-face offset shows up straight away in single-pass uniformity.

6. Precision sieves for semiconductor grading, whose stepped-frame sheets take the same overlay check.

Design and Selection Notes

1. For step stencil double-side aperture alignment control, fix the object first: this governs two-face aperture registration, not step height.

2. Do not put targets only at the four corners; lay a set in each zone and remeasure the datum at the step sheet by sheet.

3. More targets are not automatically better — four corners plus two zone sets is enough, and extra ones start fighting each other. If the thick-zone datum drifts past 5μm, go back to exposure and re-align before overlaying.

4. Give two-side undercut per thickness class and verify compensation on a sample; do not copy flat-substrate numbers.

5. Measure centre offset and ±7μm position apart; a single-side checker cannot tell whether the two faces are offset.

6. Set tension in 10–55N steps and never mix classes in one lot, so lamination does not drift the datum again.

7. Give step stencil exposure datum remeasurement its own station; a checker scanning outlines cannot replace overlay centre measurement.

Break step stencil double-side aperture alignment control apart and no single step owns it. Double-side lamination and LDI fix the datum, developing and etch each shift the outline a little, unbalanced undercut in the thick and thin zones drags the centre off, release plus anneal decide whether the step root springs back, and the overlay check finally pulls the two-face offset into the window. A flat substrate holds double-side alignment after one registration; a step stencil lets its datum drift right at the thick-thin boundary. In the shop the imaging operator pulls two sheets per bath, stacks both apertures on the imager, and pulls any sheet past ±7μm for rework instead of letting it into the good lot. Nor are more targets automatically safer. What is hard is a dozen sheets from one bath and several consecutive lots all landing on the same target set and undercut class; only then does ±5μm double-side alignment mean anything. For mixed-pad orders, fix the target layout, undercut compensation and overlay call in the process card at sampling and run to that card — cheaper than endlessly tuning blade pressure and swapping paste at the printer. Set undercut deviation against measured plant capability and stack the two faces on a sample before the drawing goes out.