Probe locating template datum re-inspection measures the template's own datums — the datum bores and the datum edge — against the probe hole pattern on two counts: the reading spread across three clampings of one piece, and hole position drift after time in storage. The basis counts the template's contribution only; test-head repeatability is measured separately on its own report and the two sheets are never stacked. In the metrology room at 23±2°C the vision system aligns to the datum bore, and three unclamp-and-refixture rounds each produce a hole map.
Three troubles show up on the floor. First, three clampings of one sheet scatter hole readings by 6 μm; production blames the test head, a second machine scatters the same way — the bill sits in the fit clearance between datum bore and locating edge. Second, a template accepted at shipping drifts 4 μm after half a year in stores; the low-temperature anneal was short and stress is still walking. Third, machine error and template error tangle together, each side waving its own numbers and the rework aimed the wrong way. All three get settled by splitting the datum account. Templates in continuous production also want a quick datum round every month — far cheaper than sweeping the whole pattern when something goes wrong.
Parameter Window
• Hole position ±7 μm on the template's own basis, machine error excluded
• Datum bore tolerance ±3 μm, two-bore centre distance ±2 μm, datum edge straightness given separately
• Clamping repeatability: spread over 3 clampings ≤2 μm, room at 23±2°C and 45–60%RH
• Long-term drift: one round each at shipping, 3 months and 6 months, hole drift ≤3 μm to pass
• Template thickness 20–200 μm; above 100 μm the rigid band distorts less under clamping
• Instruments: vision system or CMM, 0.5 μm resolution, compared against the first-article hole map
Manufacturing Process (8 Steps)
1. Datum definition — the drawing fixes datum bores and datum edge first; every hole coordinate is pulled from the datum.
2. Datum forming — both datum bores cut in one setup, centre distance held to ±2 μm, no second alignment run.
3. Hole pattern forming — LDI 8 μm/8 μm, double-side alignment ±5 μm, the whole array swept to ±7 μm.
4. Ageing — low-temperature anneal to release stress, then 48 h rest before entering the metrology room.
5. First inspection — at 23±2°C, vision aligns to the datum and sweeps the array, issuing the datum hole map.
6. Clamping repeatability re-check — unclamp and refixture three times, one map per round, spread computed across the three.
7. Drift re-check — one round each at shipping, 3 months and 6 months, every round compared with the first-article map.
8. Verdict and filing — spread ≤2 μm and drift ≤3 μm release; out of band is attributed within the template's share only.
Core Advantages
1. Datum first — every hole coordinate pulled from the datum bores, so the readings have a single origin.
2. Clamping repeatability measured directly; three readings side by side, spread not guessed by feel.
3. Drift becomes a curve — shipping, 3 months, 6 months joined up, the trend visible.
4. Responsibility drawn clean: the machine is measured elsewhere, this basis admits only the template's share.
5. Room controlled at 23±2°C and 45–60%RH, so thermal growth is out of the readings.
6. Data traces to the root — every round of hole maps hangs on the datum number and matches whatever machine it mounts on.
Typical Applications
• Wafer-test probe card locating templates, where a shifted datum misplaces every probe
• Locating templates for probe-station clamping, where frequent changeovers live on repeatability
• Burn-in board locating fixtures, where six months in stores is what they eat
• LED array probe locating, small balls and thin position margin
• Sensor test locating templates across multiple stations and clampings
• Long-term spare templates, re-checked on this basis before leaving stores
Design and Selection Notes
1. Datum first. Hole coordinates come from the datum bores; do not let every hole find its own origin.
2. Measure machine error apart. Template re-check happens in the metrology room; machine repeatability gets its own report and the two sheets do not stack.
3. Tighter is not automatically better — over-clamping bows a thin template, most obvious in the 20–50 μm band.
4. If the spread over three clampings passes 2 μm, go back and re-check the datum bore fit and locating edge before touching the test head.
5. Give ageing its time; readings inside 48 h of the anneal do not count, stress is still moving.
6. Put room conditions on the report — 23±2°C, 45–60%RH; across 50 mm a 5°C swing is already 3 μm.
7. Templates drifting past 3 μm get downgraded or scrapped; forcing them on only drags batch after batch of probes off position.
In the metrology room, probe locating template datum re-inspection is three clampings and two curves. At 23±2°C the inspector aligns to the datum bore, measures, unclamps, refixtures and measures again; three rounds scatter 1.6 μm and release at ≤2 μm. The same sheet re-tested after 6 months in stores has drifted 2.4 μm overall, still inside the ≤3 μm band. Both numbers are the template's account alone: machine repeatability is measured separately, test-head error never enters this table, and that is how responsibility stays split. Probe locating template datum re-inspection and hole position accuracy run as a pair — ±7 μm governs the static figure, spread ≤2 μm governs every clamping, drift ≤3 μm governs time, each with its own budget. If the three-clamping spread passes 2 μm on two sheets in a row, go back and re-check bore fit and locating edge instead of just recalibrating the machine. Clamping is not better for being tighter either: a 20–50 μm thin template bows under over-clamping and the readings scatter worse. For orders that sit in stores, rotate across stations or serve as long-term spares, write the clamping count, spread limit, drift limit and the 3-month/6-month re-check points into the acceptance sheet. What ships is the hole record with spread ≤2 μm, drift ≤3 μm and only the template's share inside it.
Contact:赖先生
Phone:+86 18938693450
Tel:0755-2708-8292
Email:yw9@zldsmt.com
Add:深圳市宝安区福永镇新和村福园一路华发工业园A3栋